Features SPO2+NIBP+TEMP+ETCO2 l Accurate measurement in 0.05% Low perfusion Index,the word leading production in the movement environment
l Provide the parameter of PI( Perfusion Index 0.05%-20%)
l Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients
l NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude -Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
l Easy operation by 4'' color TFT Up to 100 users ID switch
l Multiple vital signs measurement parameters for collocation optional 3/5 Leads ECG,NIBP,Spo2,Temp NIBP,Spo2,Temp,Co2
l two measurements mode:Spot,Monitoring
l Data storage capabilities, support for historical data view and trend chart back to see In monitoring mode, can continuously record 48 hours of measurement data In spot mode,100 users ID, each user can store 200sets data
l Support audio and visual alarm,support to set alarm upper and lower limit values
l Lithium ion battery power supply Performance Specifications Heart Rate:
Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Accuracy ±1% or ±1bpm Bigger Resolution 1 bpm Sensitivity > 200 uV (peak to peak)
Bandwidth Diagnositic 0.05 ~100 Hz Monitor 0.5 ~ 40Hz Surgery 1 ~ 20 Hz Stronger Filter 5 ~ 20Hz
l Oxygen Saturation(%Spo2) Measurement Range: Spo2: 0~100% PR:0-254bpm Perfusion Index: 0.025%-20% Accuracy range: SpO2:70%-100% PR:30-254bpm Perfusion Index: 0.05%-20% Measurement accuracySpO2 saturation: Adult (including pediatric ) ±2bpm(70%--100%) PR: ±3bpm Neonate ±3bpm not defined(<70%) PR: ±3bpm On motion condition ±5bpm
l Temperature Measurement range: 25 - 45°C Resolution: 0.1°C Accuracy: ±0.1°C Power Type: Lithium ion battery Operation time: 8 hours for normal operation Temperature: Operating: 0ºC~45ºC Starage/ Transportation: -20ºC~65ºC Humidity: Operating: 15% to 90% noncondensing Storage: 0% to 95% noncondensing Altitude: Operating Altitude: Up to 5000 meters SIZE: Dimension 146mm*67mm*30mm Weight 250g
l Display: 3.5' ' color TFT Resolution: 320*480 Indicator: Alarm indicator,Power indicator Trace: 1 plethysmogram waveform,ECG wave Alarm: Probe off, low power Modes: Visual and Audio Application: Neonatal,pediatric and adult patients
l NIBP The wider NIDP measurement range Adult Mode SYS 40 ~270 (mmHg) MEAN 20 ~230(mmHg) DIA 10 ~210 (mmHg) Pediatric Mode SYS 40 ~ 200 (mmHg) MEAN 10 ~ 150 (mmHg) DIA 20 ~ 165 (mmHg) Neonatal Mode SYS 40 ~ 135 (mmHg) MEAN 20 ~ 105 (mmHg) DIA 10 ~ 95 (mmHg) Pulse rate range:40~240bpm NIBP measurement accuracy:±3mmHg Pulse rate measurement accuracy:<=2% (>=100 BPM) or 2 beats/min (<100 BPM)
Independent software protection pressure Adult 300mmHg PED 240mmHg NEO 150mmHg
Independent hardware protection pressure Adult 320--330mmHg PED 265--275mmHg NEO 160--165mmHg ETCO2
|