RSD6000 Hospital Diagnostic Machine Patient Monitor ECG SPO2 NIBP TEMP PR RESP 6Parameters
Features:
Standard configuration:SPO2,ECG,NIBP,TEMP,RESP
8inch high brightness, high resolution color TFT LED display
Waterproof , fanless design, low energy consumption
Built-in rechargeable Li-battery working up-to 5 hours for field monitoring, ambulance and short term transportation
Clear bright and Large character display , NIBP measurement review, one-click operation, unique Vector display
7 channel ECG waveform display;ST-segment analysis
Application:Adult,pediatric,neonate;
working mode: diagnosis,monitor and surgery
13 kinds of arrhythmia analysis and 15 kinds of drug dose calculation
High-frequency electric surgical knives(300W),defibrillation and ESU protection
New SpO2 technology to ensure the accuracy and low perfusion upto 0.2% measurement
Intelligent audio and visual alarm function
Optional parts:HDMI ;EtCO2;touch screen
Specifications:
ECG
ECG Cable: Standard 3/ 5 leads
3 Leads:RA,LA,LL,Leads section:I,II,III
5 Leads:RA,LA,LL,RL,V, Leads section:I,II,III/aVR,aVL,aVF/V
Gain selection:´0.25,´0.5,´1,´2
Heart Rate Range:
Adult:15 ~ 300bpm
Children/Infant/Neonate:15 ~ 350 bpm
Accuracy:±1% or ±1bpm
Resolution:1 bpm Sensitivity >200 uV(Peak to peak)
Input Resistance >5(MΩ)
Bandwidth:
Diagnosis :0.05~130Hz
Monitor:0.5~40Hz
Surgery :1~20Hz
ST segment deviation analysis:
Range:-0.8 mV~+0.8mV
Accuracy:±2.0mV
NIBP:
Work mode: Manual, Automatic, Continuous
Unit: mmHg, Kpa
Measurement Range:
Adult: SYS: 40~270mmHg
DIA: 10~215mmHg
MEAN:20~240mmHg
Pediatric: SYS:40~200mmHg
DIA: 10~150mmHg
MEAN:20~165mmHg
Neonatal:SYS:40~135mmHg
DIA:10~100mmHg
MEAN:20~110mmHg
Resolution:1mmHg
Measurement Type :SYS,DIA,MEAN
Overpressure protection
Adult: 300mmHg
Pediatric :240mmHg
Infant/Neonate :150mmHg
SpO2
Measurement range:0~100%
Resolution:1%
Accuracy:±2(70~100%)
Pulse rate
Measurment range:20~300bpm
Resolution:1bpm
Accuracy:±3bpm
Respiration:
Measurement Range:
Adult: 2~120BrPM
Child/Infant/Neonate:2~150 BrPM
Resolution:1 BrPM
Accuracy:±2 BrPM
Asphyxiation alarm: 10~40 seconds
Resolution:1BrPM
Accuracy:±2%
TEMP:
Channel Number: 2
Measurement Range: 0~50°C
Resolution : 0.1°C
Accuracy:±0.1°C
Response time: ≤ 3min
Power requirement
Voltage:90~245V AC 50/60Hz
Power Consumption:15W
Battery:14.8V 2200mAH Li- Battery
Battery life: 5 hours
DC: 12~20V/2A
Working Environment:
Operating Temperature:0 ~ 40 (°C)
Transport and Storage Temperature:-20~60 (°C)
Working Humidity ≤ 85 %
Transport and Storage Humidity: ≤ 93 %
|