Model NO.
RSD7000B
Classification
Physiological Functions of Diagnosis and Monitoring Equipment
Type
Patient Monitor
Certification
CE, MSDS, ISO13485
Group
Adult,Neo,PED
Parameters
NIBP,SpO2,Temp,ECG,Resp
Application
Adult, Neonate ,Child
Optional Function
Etco2,IBP,HDMI,Touch Screen
Trademark
Ronseda
Specification
12.1inch
Origin
China

Product Description

RSD 7000B

1.Details                                                                                                                           

 

 

StandardSPO2,ECG,NIBP,TEMP,Resp
OpintalHDMI ;IBP;EtCO2;touch screen
Size12.1inch high brightness, high resolution color TFT LED display
PowerLi-Battery (rechargeable)

 

 

2.Parameters                                                                                                                  

 

 

 ECG 
ECG Cable: Standard 3/ 5 leads
3 Leads:RA,LA,LL,Leads section:I,II,III
5 Leads:RA,LA,LL,RL,V, Leads section:I,II,III/aVR,aVL,aVF/V
Gain selection:´0.25,´0.5,´1,´2
Heart Rate Range:
Adult:15 ~ 300bpm
Children/Infant/Neonate:15 ~ 350 bpm
Accuracy:±1% or ±1bpm
Resolution:1 bpm Sensitivity >200 uV(Peak to peak)
Input Resistance >5(MΩ)
Bandwidth:
Diagnosis :0.05~130Hz
Monitor:0.5~40Hz
Surgery :1~20Hz
ST segment deviation analysis:
Range:-0.8 mV~+0.8mV
Accuracy:±2.0mV
 NIBP 
Work mode: Manual, Automatic, Continuous
Unit: mmHg, Kpa
Measurement Range:
Adult: SYS: 40~270mmHg
DIA: 10~215mmHg
MEAN:20~240mmHg
Pediatric: SYS:40~200mmHg
DIA: 10~150mmHg
MEAN:20~165mmHg
Neonatal:SYS:40~135mmHg
DIA:10~100mmHg
MEAN:20~110mmHg
Resolution:1mmHg
Measurement Type :SYS,DIA,MEAN
Overpressure protection
Adult: 300mmHg
Pediatric :240mmHg
Infant/Neonate :150mmHg
 SpO2  
Measurement range:0~100%
Resolution:1%
Accuracy:±2(70~100%)
Pulse rate
Measurment range:20~300bpm
Resolution:1bpm
Accuracy:±3bpm
 Respiration 
Measurement Range:
Adult: 2~120BrPM
Child/Infant/Neonate:2~150 BrPM
Resolution:1 BrPM
Accuracy:±2 BrPM
Asphyxiation alarm: 10~40 seconds
Resolution:1BrPM
Accuracy:±2%
 TEMP 
Channel Number: 2
Measurement Range: 0~50°C
Resolution : 0.1°C
Accuracy:±0.1°C
Response time: ≤ 3min
 Power requirement 
Voltage:90~245V AC 50/60Hz
Power Consumption:15W
Battery:14.8V 2200mAH Li- Battery
Battery life: 5 hours
DC: 12~20V/2A
 Working Environment 
Operating Temperature:0 ~ 40 (°C)
Transport and Storage Temperature:-20~60 (°C)
Working Humidity ≤ 85 %
Transport and Storage Humidity: ≤ 93 %

 

3.Packing Details                                                                                   

 

 

Item N.W/
Item Size/
Packing G.W/
Packing Size/

 

 

4.Trading Terms                                                                                    

 

Trading TermsEXW, CIF, FOB
Payment TermsT/T, Paypal, Western Union
Transport wayExpress(DHL, UPS, TNT, FEDEX etc) Ocean and air

Leading time

5 to 7 working days

 

 


 
 
 
 
Send your message to this supplier
Miss Tina Chen

Post a Sourcing Request Now

People who liked this also liked
Get Quick Quotes